Marca: Seagate
Modelo: ST9160314AS-9HH13C
Fecha de Fabricación: 10376
Número de Serie: 6VC3VNZD
Lugar de Fabricación: China
Factor de Forma: HDD 2.5"
Conexión: SATA
Capacidad: 160
Estado del Disco: Sectores defec, pide cambio
PCB Nº 100535597 RevD
PCB Sticker: 100535602 H
MCU:
De Frente De Dorso Del PCB
De Dorso Del PCB
Del PCB
S.M.A.R.T & Informe (2) ST9160314AS ---------------------------------------------------------------------------- Enclosure : ST916031 4AS USB Device (V=152D, P=2329, jm1) - st Model : ST9160314AS Firmware : 0005HPM1 Serial Number : 6VC3VNZD Disk Size : 160,0 GB (8,4/137,4/160,0/160,0) Buffer Size : 8192 KB Queue Depth : 32 # of Sectors : 312581808 Rotation Rate : 5400 RPM Interface : USB (Serial ATA) Major Version : ATA8-ACS Minor Version : ATA8-ACS version 4 Transfer Mode : SATA/300 Power On Hours : 938 horas Power On Count : 955 veces Temparature : 31 C (87 F) Health Status : Riesgo Features : S.M.A.R.T., APM, 48bit LBA, NCQ APM Level : 8080h [ON] AAM Level : ---- HD Tune Pro: ST9160314AS Health ID Current Worst ThresholdData Status (01) Raw Read Error Rate 85 77 6 154861804 ok (03) Spin Up Time 99 99 0 0 ok (04) Start/Stop Count 100 100 0 958 ok (05) Reallocated Sector Count 100 100 36 0 ok (07) Seek Error Rate 75 60 30 30442598 ok (09) Power On Hours Count 99 99 0 938 ok (0A) Spin Retry Count 100 100 97 0 ok (0C) Power Cycle Count 100 37 20 955 ok (B7) SATA Downshift Count 100 253 0 0 ok (B8) End To End Error Detection 100 100 97 0 ok (BB) Uncorrectable Error Count 1 1 0 1025 ok (BC) Command Timeout 100 98 0 3 ok (BD) Unknown Attribute 100 100 0 0 ok (BE) Airflow Temperature 69 56 45 522125343 ok (BF) G-sense Error Rate 100 100 0 88 ok (C0) Unsafe Shutdown Count 100 100 0 97 ok (C1) Load Cycle Count 95 95 0 10884 ok (C2) Temperature 31 44 0 42949672991 ok (C3) Hardware ECC Recovered 63 62 0 154861804 ok (C4) Reallocated Event Count 100 100 36 0 ok (C5) Current Pending Sector 100 100 0 1 warning (C6) Offline Uncorrectable 100 100 0 0 ok (C7) Interface CRC Error Count 200 200 0 0 ok Health Status : warning ### SYSTEM INFORMATION ### Report Timestamp : 3 de enero de 2018 15:49:53 ART Report Timestamp (ISO 8601 format) : 2018-01-03T15:49:53 Application Name : DriveDx Application Version : 1.7.0.570 Application SubBuild : 0 Application Edition : Standalone Application Website : https://binaryfruit.com/drivedx DriveDx Knowledge Base Revision : 8/8 Computer Name : MacBook Pro de Adrian Host Name : MacBook-Pro-de-Adrian Computer Model : MacBookPro11,5 OS Boot Time : 2018-01-03T08:55:31 Time Since Boot : 06h 54m 22s OS Name : macOS OS Version : 10.13.2 OS Build : 17C88 OS Kernel Version : Darwin 17.3.0 SAT SMART Driver Version : 0.8.1s ATA Command Support Tolerance : verypermissive N of drives in report : 1 ### DRIVE 1 OF 1 ### Last Checked : 3 de enero de 2018 15:49:23 ART Last Checked (ISO 8601 format) : 2018-01-03T15:49:23 Advanced SMART Status : FAILING Overall Health Rating : N/A 100% Overall Performance Rating : GOOD 100% Issues found : 3 Serial Number : 6VC3VNZD WWN Id : 5 000c50 02252f41a Volumes : Untitled Device Path : /dev/disk2 Total Capacity : 160.0 GB (160.041.885.696 Bytes) Model Family : Seagate Momentus 5400.6 Model : ST9160314AS Form Factor : 2.5 inches Firmware Version : 0005HPM1 Drive Type : HDD 5400 rpm Power On Time : 938 hours (1 months 9 days 2 hours) Power Cycles Count : 956 Current Power Cycle Time : 6.9 hours === DEVICE CAPABILITIES === S.M.A.R.T. support enabled : yes DriveDx Active Diagnostic Config : Seagate HDDs config [hdd.seagate] Sector Logical Size : 512 Sector Physical Size : 512 Physical Interconnect : USB Logical Protocol : USB Removable : yes Ejectable : no ATA Version : ATA8-ACS T13/1699-D revision 4 SATA Version : SATA 2.6, 3.0 Gb/s I/O Path : IOService:/AppleACPIPlatformExpert/PCI0@0/AppleACPIPCI/XHC1@14/XHC1@14000000/SSP1@14500000/USB@14500000/IOUSBHostInterface@0/IOUSBMassStorageInterfaceNub/IOUSBMassStorageDriverNub/IOUSBMassStorageUASDriver/IOSCSITargetDevice/IOSCSIHierarchicalLogicalUnit@0000000000000000/org_dungeon_driver_IOSATDriver/IOSATServices Enclosure Vendor Id / Product Id : 0xbc2 / 0xa013 SAT Pass Through Mode : Attributes Data Structure Revision : 10 SMART Command Transport (SCT) flags : 0x103f SCT Status supported : yes SCT Feature Control supported : yes SCT Data Table supported : yes Error logging capabilities : 0x1 Self-tests supported : yes Offline Data Collection capabilities : 0x53 Offline Data Collection status : 0x0 Auto Offline Data Collection flags : 0x0 [Known device ]: yes [Drive State Flags ]: 0x44000100 [Last State Change Timestamp ]: 2018-01-03T15:49:23 [Last State Change Flags ]: 0x44000100 [Last State Change Diff Flags ]: 0x1 === CURRENT POWER CYCLE STATISTICS === Data Read : 12.6 MB Data Written : 64.0 MB Data Read/Write Ratio : 0.20 Average Throughput (Read) : 10.2 MB/s Average Throughput (Write) : 68.2 MB/s Operations (Read) : 219 Operations (Write) : 129 Operations Read/Write Ratio : 2 Throughput per operation (Read) : 59.1 KB/Op Throughput per operation (Write) : 508.0 KB/Op Latency Time (Read) : 0 ns Latency Time (Write) : 0 ns Retries (Read) : 0 Retries (Write) : 0 Errors (Read) : 0 Errors (Write) : 0 === PROBLEMS SUMMARY === Failed Indicators (life-span / pre-fail) : 0 (0 / 0) Failing Indicators (life-span / pre-fail) : 1 (1 / 0) Warnings (life-span / pre-fail) : 1 (1 / 0) Recently failed Self-tests (Short / Full) : 0 (0 / 0) I/O Error Count : 0 (0 / 0) Time in Under temperature : 0 minutes Time in Over temperature : 1 minutes === IMPORTANT HEALTH INDICATORS === ID NAME RAW VALUE STATUS 5 Reallocated Sector Count 0 100% OK 183 SATA Downshift Count 0 100% OK 187 Reported Uncorrectable Errors 1.025 1.0% Failing 197 Current Pending Sector Count 1 100% Warning 198 Offline Uncorrectable Sector Count 0 100% OK 199 UDMA CRC Error Count 0 100% OK === TEMPERATURE INFORMATION (CELSIUS) === Current Temperature : 27 Power Cycle Min Temperature : 27 Power Cycle Max Temperature : 27 Lifetime Min Temperature : 10 Lifetime Max Temperature : 44 Recommended Min Temperature : 5 Recommended Max Temperature : 55 Temperature Min Limit : 5 Temperature Max Limit : 60 === DRIVE HEALTH INDICATORS === ID | NAME | TYPE | UPDATE | RAW VALUE | VALUE | THRESHOLD | WORST | LAST MODIFIED | STATUS 1 Raw Read Error Rate Pre-fail online 0x93C11DB 85 6 77 3/1/18 15:49 100% OK 3 Spin Up Time Life-span online 0 99 0 99 3/1/18 15:49 99.0% OK 4 Start Stop Count Pre-fail online 959 100 0 100 3/1/18 15:49 100% OK 5 Reallocated Sector Count Pre-fail online 0 100 36 100 3/1/18 15:49 100% OK 7 Seek Error Rate Pre-fail online 0x1D08495 75 30 60 3/1/18 15:49 100% OK 9 Power On Hours Life-span online 938 99 0 99 3/1/18 15:49 99.0% OK 10 Spin Retry Count Pre-fail online 0 100 97 100 3/1/18 15:49 100% OK 12 Power Cycle Count Pre-fail online 956 100 20 37 3/1/18 15:49 100% OK 183 SATA Downshift Count Life-span online 0 100 0 253 3/1/18 15:49 100% OK 184 End-to-End Error Pre-fail online 0 100 97 100 3/1/18 15:49 100% OK 187 Reported Uncorrectable Errors Life-span online 1.025 1 0 1 3/1/18 15:49 1.0% Failing 188 Command Timeout Life-span online 3 100 0 98 3/1/18 15:49 100% OK 189 High Fly Writes Life-span online 0 100 0 100 3/1/18 15:49 100% OK 190 Airflow Temperature Celsius Life-span online 28 72 45 56 3/1/18 15:49 49.1% OK 191 G-Sense Error Rate Life-span online 88 100 0 100 3/1/18 15:49 100% OK 192 Power-Off Retract Count Life-span online 97 100 0 100 3/1/18 15:49 100% OK 193 Load Cycle Count Life-span online 10.886 95 0 95 3/1/18 15:49 95.0% OK 194 Temperature (Celsius) Life-span online 28 72 40 56 3/1/18 15:49 53.3% OK 195 Hardware ECC Recovered Life-span online 0x93C11DB 63 0 62 3/1/18 15:49 100% OK 196 Reallocated Event Count Pre-fail online 0 100 36 100 3/1/18 15:49 100% OK 197 Current Pending Sector Count Life-span online 1 100 0 100 3/1/18 15:49 100% Warning 198 Offline Uncorrectable Sector Count Life-span offline 0 100 0 100 3/1/18 15:49 100% OK 199 UDMA CRC Error Count Life-span online 0 200 0 200 3/1/18 15:49 100% OK === DRIVE ERROR LOG === # | TIME OCCURRED | ERRORS | PRIOR COMMAND 5 926 hours UNKNOWN ERROR READ FPDMA QUEUED 4 926 hours UNKNOWN ERROR READ FPDMA QUEUED 3 926 hours UNKNOWN ERROR READ FPDMA QUEUED 2 926 hours UNKNOWN ERROR READ FPDMA QUEUED 1 926 hours UNKNOWN ERROR READ FPDMA QUEUED === DRIVE SELF-TEST LOG === # | LIFETIME (H) | TEST TYPE | PROGRESS | STATUS | LBA of 1st error 1 926 Extended captive 10% Completed: read failure 169537286 2 925 Extended captive 10% Completed: read failure 169537286 3 925 Extended captive 10% Completed: read failure 169537286 4 925 Short captive 10% Completed: read failure 169537286 5 922 Extended captive 10% Completed: read failure 169537286 6 922 Short captive 10% Completed: read failure 169537286
Cargado Por: