Dispositivo Marca: Toshiba
Modelo: MK2035GSS
Fecha de Fabricación:
Número de Serie:
Lugar de Fabricación: Philippines
Factor de Forma: HDD 2.5"
Conexión: SATA
Capacidad: 200
Estado del Disco: Sectores defec, pide cambio
Datos del PCB (o Placa Lógica) PCB Nº T G5B001 5 90000-A
PCB Sticker:
MCU:
Adjuntos: De Frente De Dorso Del PCB
Detalles S.M.A.R.T & Informe location: /dev/disk2
partition count: 2
partitions: Reservado para el sistema, Untitled,
SMART Support: Supported
Last SMART Error: *not set*
Model Family: Toshiba 2.5" HDD (80 GB and above)
Model: TOSHIBA MK2035GSS
Serial Number: 87KLTBACT
Firmware Version: DK020M
Capacity: 200 GB
ATA Version: 7
SATA Version: *not set*
Rotation Rate: *not set*
Health: Failing
Overall Health: PASSED
Offline Data Status: 0
Self Test Status: 0
Offline Data Collection Time: 120
Data Collection Capabilities: 5B
SMART Capabilities: 3
Error Logging Capabilities: 1
Short Self Test Time: 2
Long Self Test Time: 130
Conveyance Self Test Time: 0
Attribute Log Revision: 16
Attribute Count: 23
Attributes:
ID# ATTRIBUTE NAME FLAG VALUE WORST THRESH TYPE UPDATED FAILED RAW VALUE
1 Raw Read Error Rate 0x000B 100 100 050 Pre-fail Always Never 0
2 Throughput Performance 0x0005 100 100 050 Pre-fail Offline Never 0
3 Spin Up Time 0x0027 100 100 001 Pre-fail Always Never 1134
4 Start/Stop Count 0x0032 100 100 000 Old age Always Never 6146
5 Reallocated Sector Count 0x0033 100 100 050 Pre-fail Always Never 4
7 Seek Error Rate 0x000B 100 100 050 Pre-fail Always Never 0
8 Seek Time Performance 0x0005 100 100 050 Pre-fail Offline Never 0
9 Power On Hours 0x0032 061 061 000 Old age Always Never 15663
10 Spin Retry Count 0x0033 222 100 030 Pre-fail Always Never 0
12 Power Cycle Count 0x0032 100 100 000 Old age Always Never 5815
192 Power Off Retract Count 0x0032 100 100 000 Old age Always Never 396
193 Load Cycle Count 0x0032 072 072 000 Old age Always Never 282238
194 Temperature Celsius 0x0022 100 100 000 Old age Always Never 26
196 Reallocated Event Count 0x0032 100 100 000 Old age Always Never 4
197 Current Pending Sector Count 0x0032 100 100 000 Old age Always Never 0
198 Offline Uncorrectable Sector Count 0x0030 100 100 000 Old age Offline Never 0
199 UDMA CRC Error Count 0x0032 200 200 000 Old age Always Never 5
220 Disk Shift 0x0002 100 100 000 Old age Always Never 40
222 Loaded Hours 0x0032 074 074 000 Old age Always Never 10627
223 Load Retry Count 0x0032 100 100 000 Old age Always Never 0
224 Load Friction 0x0022 100 100 000 Old age Always Never 0
226 Load-in Time 0x0026 100 100 000 Old age Always Never 287
240 Head Flying Hours 0x0001 100 100 001 Pre-fail Offline Never 0
Error Log Version: 1
Error Count: 7
Error Log:
Error 7 occured at disk power-on lifetime: 6341 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 23 8F 44 60
Error: Interface CRC error, Interface CRC error with 1 sectors at LBA = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 50 D0 8E 44 60 00 00:28:19.020 READ DMA EXT
25 00 08 E8 64 4B 60 00 00:28:19.006 READ DMA EXT
25 00 08 88 BC 30 60 00 00:28:19.005 READ DMA EXT
25 00 08 C0 8C 4C 60 00 00:28:19.004 READ DMA EXT
25 00 10 90 BC 30 60 00 00:28:18.986 READ DMA EXT
Error 6 occured at disk power-on lifetime: 6313 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 22 88 81 60
Error: Interface CRC error, Interface CRC error with 1 sectors at LBA = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 40 E0 87 81 60 00 02:19:40.675 READ DMA EXT
25 00 08 A8 6F 30 60 00 02:19:40.628 READ DMA EXT
25 00 08 20 F1 34 60 00 02:19:40.627 READ DMA EXT
25 00 08 30 F1 34 60 00 02:19:40.627 READ DMA EXT
25 00 08 18 F1 34 60 00 02:19:40.613 READ DMA EXT
Error 5 occured at disk power-on lifetime: 4034 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 C5 C8 08 E7
Error: Interface CRC error, Interface CRC error with 1 sectors at LBA = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 00 C0 C7 08 E0 00 00:26:43.293 READ DMA EXT
35 00 20 60 3C 3B E0 00 00:26:43.243 WRITE DMA EXT
35 00 00 60 FC 42 E0 00 00:26:43.241 WRITE DMA EXT
35 00 00 60 FB 42 E0 00 00:26:43.239 WRITE DMA EXT
35 00 00 60 FA 42 E0 00 00:26:43.237 WRITE DMA EXT
Error 4 occured at disk power-on lifetime: 3605 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 27 AF 2F 60
Error: Interface CRC error, Interface CRC error with 1 sectors at LBA = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 60 C0 AE 2F 60 00 01:39:14.231 READ DMA EXT
35 00 20 60 97 84 60 00 01:39:14.017 WRITE DMA EXT
35 00 A0 C0 7B 86 60 00 01:39:14.016 WRITE DMA EXT
25 00 A0 00 AE 2F 60 00 01:39:14.012 READ DMA EXT
35 00 20 60 97 84 60 00 01:39:13.950 WRITE DMA EXT
Error 3 occured at disk power-on lifetime: 1083 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 DC 5C 70 39 60
Error: Uncorrectable Error with 220 sectors at LBA = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 F8 40 70 39 60 00 05:37:02.631 READ DMA EXT
25 00 51 D8 70 BB 60 00 05:37:02.603 READ DMA EXT
25 00 00 D8 6F BB 60 00 05:37:02.601 READ DMA EXT
25 00 31 F8 70 BB 60 00 05:37:02.600 READ DMA EXT
25 00 21 08 71 BB 60 00 05:37:02.595 READ DMA EXT
Self Test Log Revision: 1
Self Test Log Count: 0
Self Test Log:
No self tests logged.
Cargado Por: