Toshiba MK2561GSYN 250GB SATA | RecuperoDatos.com

Toshiba MK2561GSYN 250GB SATA

Mensaje de error

  • Warning: strpos(): Empty needle en _decomposeDiscoForURL() (línea 867 de /home/adrianf25/public_html/sites/all/modules/custom/recuperodatos_custom/recuperodatos_custom.module).
  • Warning: strpos(): Empty needle en _decomposeDiscoForURL() (línea 867 de /home/adrianf25/public_html/sites/all/modules/custom/recuperodatos_custom/recuperodatos_custom.module).
  • Warning: strpos(): Empty needle en _decomposeDiscoForURL() (línea 867 de /home/adrianf25/public_html/sites/all/modules/custom/recuperodatos_custom/recuperodatos_custom.module).
  • Warning: strpos(): Empty needle en _decomposeDiscoForURL() (línea 867 de /home/adrianf25/public_html/sites/all/modules/custom/recuperodatos_custom/recuperodatos_custom.module).
  • Warning: strpos(): Empty needle en _decomposeDiscoForURL() (línea 867 de /home/adrianf25/public_html/sites/all/modules/custom/recuperodatos_custom/recuperodatos_custom.module).
Dispositivo

Marca:  Toshiba

Modelo:  MK2561GSYN

Fecha de Fabricación:  22SEP2011

Número de Serie:  

Lugar de Fabricación:  Thailand

Factor de Forma:  HDD 2.5"

Conexión:  SATA

Capacidad:  250

Estado del Disco:  Sectores defec, pide cambio

Datos del PCB (o Placa Lógica)

PCB Nº  G002872A

PCB Sticker:  

MCU:  

Adjuntos:

De Frente  toshiba-MK2561GSYN

De Dorso  toshiba-MK2561GSYN

Del PCB  

Detalles

S.M.A.R.T & Informe  
location: /dev/disk2
partition count: 0

SMART Support: Supported
Last SMART Error: *not set*
Model Family: Toshiba 2.5" HDD MK..61GSY[N]
Model: TOSHIBA MK2561GSYN
Serial Number: 91M4B41IB
Firmware Version: MH000D
Capacity: 250 GB
ATA Version: 8
SATA Version: SATA 2.6, 3.0 Gb/s (current: 1.5 Gb/s)
Rotation Rate: 7200 rpm
Health: Failing
Overall Health: PASSED
Offline Data Status: 0
Self Test Status: 37
Offline Data Collection Time: 120
Data Collection Capabilities: 5B
SMART Capabilities: 3
Error Logging Capabilities: 1
Short Self Test Time: 2
Long Self Test Time: 64
Conveyance Self Test Time: 0
Attribute Log Revision: 128
Attribute Count: 15
Attributes:
ID# ATTRIBUTE NAME FLAG VALUE WORST THRESH TYPE UPDATED FAILED RAW VALUE
1 Raw Read Error Rate 0x000B 100 100 050 Pre-fail Always Never 0
3 Spin Up Time 0x0027 100 100 001 Pre-fail Always Never 1302
5 Reallocated Sector Count 0x0033 100 100 050 Pre-fail Always Never 0
9 Power On Hours 0x0032 094 094 000 Old age Always Never 164138
12 Power Cycle Count 0x0032 100 100 000 Old age Always Never 2320
191 G-Sense Error Rate 0x0032 100 100 000 Old age Always Never 238
192 Power Off Retract Count 0x0032 100 100 000 Old age Always Never 416
193 Load Cycle Count 0x0032 098 098 000 Old age Always Never 29828
194 Temperature Celsius 0x0022 100 100 000 Old age Always Never 26
199 UDMA CRC Error Count 0x0032 100 100 000 Old age Always Never 30404237
200 Multi Zone Error Rate 0x0032 100 100 000 Old age Always Never 76379376
240 Head Flying Hours 0x0032 096 096 000 Old age Always Never 103025
241 Total LBAs Written 0x0032 100 100 000 Old age Always Never 8025454582
242 Total LBAs Read 0x0032 100 100 000 Old age Always Never 11197094782
254 Free Fall Sensor 0x0032 100 100 000 Old age Always Never 12
Error Log Version: 1
Error Count: 376
Error Log:
Error 376 occured at disk power-on lifetime: 2735 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 41 A2 37 B1 22 60
Error: Interface CRC error, Interface CRC error
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 40 A0 F8 B0 22 40 00 00:00:58.263 READ FPDMA QUEUED
60 40 98 B8 B0 22 40 00 00:00:58.257 READ FPDMA QUEUED
60 40 90 F0 B1 22 40 00 00:00:58.249 READ FPDMA QUEUED
60 40 88 50 82 22 40 00 00:00:58.249 READ FPDMA QUEUED
60 40 80 10 82 22 40 00 00:00:58.245 READ FPDMA QUEUED

Error 375 occured at disk power-on lifetime: 2735 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 41 80 8F 19 11 60
Error: Interface CRC error, Interface CRC error
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
61 08 78 90 1A 11 40 00 00:17:07.987 WRITE FPDMA QUEUED
61 08 70 88 1A 11 40 00 00:17:07.987 WRITE FPDMA QUEUED
61 08 68 80 1A 11 40 00 00:17:07.987 WRITE FPDMA QUEUED
61 08 60 78 1A 11 40 00 00:17:07.987 WRITE FPDMA QUEUED
61 08 58 70 1A 11 40 00 00:17:07.987 WRITE FPDMA QUEUED

Error 374 occured at disk power-on lifetime: 2734 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 41 60 5F 7B 1B 60
Error: Interface CRC error, Interface CRC error
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
61 95 18 E0 A2 1B 40 00 00:02:10.755 WRITE FPDMA QUEUED
61 02 10 D8 A2 1B 40 00 00:02:10.755 WRITE FPDMA QUEUED
61 1B 08 B8 A2 1B 40 00 00:02:10.754 WRITE FPDMA QUEUED
61 82 00 30 A2 1B 40 00 00:02:10.754 WRITE FPDMA QUEUED
61 00 60 60 7A 1B 40 00 00:02:10.753 WRITE FPDMA QUEUED

Error 373 occured at disk power-on lifetime: 2734 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 41 B2 F3 77 4E 60
Error: Interface CRC error, Interface CRC error
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 3A B0 BA 77 4E 40 00 00:01:54.124 READ FPDMA QUEUED
60 13 A8 00 78 4E 40 00 00:01:54.120 READ FPDMA QUEUED
60 08 A0 E0 75 4E 40 00 00:01:54.114 READ FPDMA QUEUED
60 3C 98 E2 17 48 40 00 00:01:54.110 READ FPDMA QUEUED
60 14 90 3A 1B 48 40 00 00:01:54.109 READ FPDMA QUEUED

Error 372 occured at disk power-on lifetime: 2734 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 41 EA 69 EF 6D 60
Error: Interface CRC error, Interface CRC error
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 40 E8 2A EF 6D 40 00 00:01:55.322 READ FPDMA QUEUED
60 40 E0 EA EE 6D 40 00 00:01:55.318 READ FPDMA QUEUED
60 40 D8 AA EE 6D 40 00 00:01:55.317 READ FPDMA QUEUED
60 40 D0 6A EE 6D 40 00 00:01:55.316 READ FPDMA QUEUED
60 08 C8 88 BE 61 40 00 00:01:55.305 READ FPDMA QUEUED

Self Test Log Revision: 1
Self Test Log Count: 2
Self Test Log:

Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Interrupted (host reset) 50% 2727 -
# 2 Short offline Completed without error 0% 2726 -