Marca: Western Digital
Modelo: WD3200BPVT-00HXZT3
Fecha de Fabricación: 07 JUN 2012
Número de Serie: WXC1E32ZPW50
Lugar de Fabricación: Malaysia
Factor de Forma: HDD 2.5"
Conexión: SATA
Capacidad: 320
Estado del Disco: Usado pero OK
PCB Nº 2060-771820-000 REV A
PCB Sticker: 771820-800 AF
MCU:
De Frente De Dorso Del PCB
De Dorso Del PCB
Del PCB
S.M.A.R.T & Informe location: /dev/disk2 partition count: 0 SMART Support: Supported Last SMART Error: *not set* Model Family: Western Digital Scorpio Blue Serial ATA (AF) Model: WDC WD3200BPVT-00HXZT3 Serial Number: WD-WXC1E32ZPW50 Firmware Version: 01.01A01 Capacity: 320 GB ATA Version: 8 SATA Version: SATA 2.6, 3.0 Gb/s Rotation Rate: 5400 rpm Health: Passed Overall Health: PASSED Offline Data Status: 0 Self Test Status: 0 Offline Data Collection Time: 7800 Data Collection Capabilities: 7B SMART Capabilities: 3 Error Logging Capabilities: 1 Short Self Test Time: 2 Long Self Test Time: 79 Conveyance Self Test Time: 5 Attribute Log Revision: 16 Attribute Count: 17 Attributes: ID# ATTRIBUTE NAME FLAG VALUE WORST THRESH TYPE UPDATED FAILED RAW VALUE 1 Raw Read Error Rate 0x002F 200 200 051 Pre-fail Always Never 3 3 Spin Up Time 0x0027 184 180 021 Pre-fail Always Never 1800 4 Start/Stop Count 0x0032 100 100 000 Old age Always Never 405 5 Reallocated Sector Count 0x0033 200 200 140 Pre-fail Always Never 0 7 Seek Error Rate 0x002E 200 200 000 Old age Always Never 0 9 Power On Hours 0x0032 100 100 000 Old age Always Never 309 10 Spin Retry Count 0x0032 100 100 000 Old age Always Never 0 11 Calibration Retry Count 0x0032 100 100 000 Old age Always Never 0 12 Power Cycle Count 0x0032 100 100 000 Old age Always Never 396 192 Power Off Retract Count 0x0032 200 200 000 Old age Always Never 54 193 Load Cycle Count 0x0032 197 197 000 Old age Always Never 9831 194 Temperature Celsius 0x0022 122 102 000 Old age Always Never 25 196 Reallocated Event Count 0x0032 200 200 000 Old age Always Never 0 197 Current Pending Sector Count 0x0032 200 200 000 Old age Always Never 0 198 Offline Uncorrectable Sector Count 0x0030 100 253 000 Old age Offline Never 0 199 UDMA CRC Error Count 0x0032 200 188 000 Old age Always Never 142 200 Multi Zone Error Rate 0x0008 100 253 000 Old age Offline Never 0 Error Log Version: 1 Error Count: 4 Error Log: Error 4 occured at disk power-on lifetime: 302 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 01 30 4F C2 E0 Error: Command Aborted Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- B0 D6 01 BE 4F C2 E0 00 00:12:17.484 SMART WRITE LOG B0 DA 01 00 4F C2 E0 00 00:12:17.354 SMART RETURN STATUS 80 44 00 00 44 57 E0 00 00:12:17.353 [VENDOR SPECIFIC] B0 D6 01 BE 4F C2 E0 00 00:12:17.295 SMART WRITE LOG 80 45 00 00 44 57 E0 00 00:12:17.295 [VENDOR SPECIFIC] Error 3 occured at disk power-on lifetime: 302 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 01 30 4F C2 A0 Error: Command Aborted Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- B0 D6 01 BE 4F C2 A0 00 00:08:13.700 SMART WRITE LOG B0 DA 01 00 4F C2 A0 00 00:08:13.569 SMART RETURN STATUS 80 44 00 00 44 57 A0 00 00:08:13.569 [VENDOR SPECIFIC] B0 D6 01 BE 4F C2 A0 00 00:08:13.532 SMART WRITE LOG 80 45 00 01 44 57 A0 00 00:08:13.532 [VENDOR SPECIFIC] Error 2 occured at disk power-on lifetime: 289 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 01 30 4F C2 E0 Error: Command Aborted Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- B0 D6 01 BE 4F C2 E0 00 00:05:30.786 SMART WRITE LOG B0 DA 01 00 4F C2 E0 00 00:05:30.655 SMART RETURN STATUS 80 44 00 00 44 57 E0 00 00:05:30.655 [VENDOR SPECIFIC] B0 D6 01 BE 4F C2 E0 00 00:05:30.597 SMART WRITE LOG 80 45 00 00 44 57 E0 00 00:05:30.597 [VENDOR SPECIFIC] Error 1 occured at disk power-on lifetime: 289 hours When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 01 30 4F C2 A0 Error: Command Aborted Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- B0 D6 01 BE 4F C2 A0 00 00:01:27.012 SMART WRITE LOG B0 DA 01 00 4F C2 A0 00 00:01:26.881 SMART RETURN STATUS 80 44 00 00 44 57 A0 00 00:01:26.881 [VENDOR SPECIFIC] B0 D6 01 BE 4F C2 A0 00 00:01:26.844 SMART WRITE LOG 80 45 00 01 44 57 A0 00 00:01:26.844 [VENDOR SPECIFIC] Self Test Log Revision: 1 Self Test Log Count: 2 Self Test Log: Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Conveyance offline Completed without error 0% 302 - # 2 Conveyance offline Completed without error 0% 289 -
Cargado Por: